Hotline:400-6069-106
[ Chinese ]
Location:Home > News > Text

Computer Room Monitor Solution Introduction

Published:2011-10-08 11:28

 

Standard Computer Room Monitor Solution
 
 
System advantages:
 
A, the fexible design of the system architecture
 
Modular:
Our system can cover computer room power, environment, security, fire control and many other objects according to the demands, and each subsystem can work independently and not be interfered with each other; This makes the expansion and upgrading of the system easier, user can add devices and investment in stages according to the demand and budget, which can satisfy the demand of enterprise that investment is increased with the development of the enterprise;
 
Network:
Network, IP, distributed network mode, relevant administrator can inquire the running situation of the device in computer room through Web browser, this system makes the management and maintenance work simpler, easier and more relexed;
 
Producibility:
RichComm Technologies CO.,Ltd can provide One-stop system product procurement services, producibility system architecture makes the installation, test and maintenance work more relaxed and simpler.
 
 
B, the intelligent design of system function
 
Intelligent: adapt pre-roll monitor collecting equipment, which has intelligent design and front end data processing and storage function, it can send the monitor data and warn information report to the background automatically, and can cooperate with the background server by reasonable division, through this design, our system can scatter the data processing stress, so as to improve the reliability and stability of the system comprehensively, it can also improve the real-time and accuracy of the monitor system.
 
 
Monitor object and content
 
1, Power distribution monitor system
 
RichComm computer room monitor system can monitor all kinds of parameters of the main circuit and branch circuit of level one and level two AC power distribution. Such as voltage, current, frequency, active power, power factor, reactive power, apparent power, etc; It can also monitor the switch state of all levels, display and record the curve changes of various parameters, and this system can also record all kinds of alarm status and deal with the alarm timely.
 

Precise Power Distribution Cabinet Monitor System
Netmate II mini Precise Power Distribution Cabinet Network Monitor Adapter
Used to monitor power distribution cabinet, collect the voltage, current, active power, reactive power and other data of power distribution.(One precise power distribution cabinet needs to be allocated with one Netmate II mini precise power distribution c

 
 
 
 

Common Power Distribution Cabinet Monitor System
Netmate II mini Intelligent Power Distribution Cabinet Network Monitor Adapter
Used to monitor power distribution cabinet, collect the voltage, current, active power, reactive power and other data of power distribution.(One common power distribution cabinet needs to be allocated with one Netmate II mini intelligent power distributio
Three Phase Intelligent Power Inspection
collect the voltage, current, active power, reactive power and other data of power distribution.(One common power distribution cabinet needs to be allocated with one three phase intelligent power inspection instrument)

 
2, UPS system
 
As long as the supplier provides UPS communication protocol to us, richcomm’s computer room monitor system can monitor alll kinds of parameters and status that the communication protocol provides. The parameters include input and output voltage, current, frequency, power, accumulator battery pack voltage, backup time, temperature, etc; Status includes rectifier, inverter, battery, bypass, load, etc; It can display and record the curve changes of various parameters, and this system can also record all kinds of alarm status and deal with the alarm timely.
 

UPS Power Monitor System
Netmate II mini UPS Network Monitor Adapter (internal/3 phase)
Monitor 3 phase UPS, monitor 2 circuits temperature and humidity module, can be insected into Rackslot, each UPS need one device and need to provide accurate UPS model, this device can also expand one battery power inspection instrument
Netmate II mini UPS Network Monitor Adapter (internal/1 phase)
Monitor 1 phase UPS, monitor 2 circuits temperature and humidity module, can be insected into Rackslot, each UPS need one device and need to provide accurate UPS model, this device can also expand one battery power inspection instrument

 
3, Precise air conditioning system
 
(1)       The precise air conditioning in computer room is a intelligent device, as long as it has intelligent interface, our system can monitor the running parameters of the precise air conditioning comprehensively. According to the communication protocol and remote monitor panel which is provided by the presice air conditioning supplier, our system can real time monitor the return air temperature and humidity, cooling water in and out temperature and flow rate, frozen water in and out temperature, the work current of refrigerator, forzen water pump, and many other parameters; Monitor work status includes compressor state, fan state, heater state, dehumidifier state (water-cooled air conditioning can also monitor the liquid surface state and fan state of cooling water tower, valve state of cooling water, etc) and many other work status; It can display and record the curve changes of various parameters, and this system can also record all kinds of alarm status and deal with the alarm timely. Control the open and closed status, adjust the temperature and humidity. The system can also set various parameters of the air conditioning directly.
 

Precise Air Conditioning Monitor System
Netmate II mini Precise Air Conditioning Network Monitor Host(internal)
Monitor precise air conditioning data, need to be provided protocol and interface(One precise air conditioning needs to be allocated with one Netmate II mini precise air conditioning network monitor adapter)

 
(2)       Common air conditioning: through the cuicuit modification of air conditioning, or using air conditioning infrared controller, our system can handle with the utility status, fan status, compressor status and warning information. Our system can also control the open and closed status according to the temperature and humdity changes.
 

Common Air Conditioning Monitor System
Air Conditioning Intelligent Remote Controller
it can remote control air conditioning switch state and can realize the remote restart function automatically.(one air conditioning needs one air conditioning intelligent remote controller), it needs to be allocated with Sitemate AE
Photoelectric isolated conversion module
(one air conditioning needs one air conditioning intelligent remote controller and one photoelectric isolated conversion module), this module is used to change the RS485 signal to RS422 signal, it needs to be allocated with Sitemate AE

 
 
4, Environment temperature and humidity system
 
Through the temperature and humidity data which is collected by temperature and humidity sensor, richcomm computer monitor system can real time record and display the temperature and humidity data and changes curve all area in the computer room intuitively, this system can also handle with the alarm information. What’s more, at the same time of paying attention to the computer room comprehensive environment temperature and humidity, RichComm’s computer room monitor system pays more attentions to the cabinet inner micro-environment temperature and humidity monitor.
 

Intelligent High Precision Temperature and Humidity Detection Module
Special in computer room, high precision digital temperature and humidity sensor, temprature range is -55~+155, accuracy is ±0.5℃, Modbus RTU communication interface, full-duplex mode, strong anti-interference, stable and reliable.(one device/20~30㎡ )

 
 
 
5, Fire control system interface
 
Through the alarm signal which is collected by collecting fire controller or smoke detector, temperature detector, our system can real time monitor fire warn state, when the fire occurs, RichComm’s computer room monitor system can display the warn information intuitively and send warn notice, and then adapt control measure, such as the open/closed control of ventilation equipment and other relevent devices
 

Smoke Sensor
Monitor computer room smoke situation(install one device/20~30㎡ ), user can configure according to the real size of the computer room, one smoke sensor takes one switch quantity detection terminal.

 
 
 
6, leak monitor system
 
RichComm ‘s leak detection is to monitor the area where the water leakage may be happened, such as computer air conitioning or windows, etc, our system can monitor the water leakage situation on any leak probe through the acquisition of alarm signal on leak detection host, once the alarm occurs, the computer room monitor system will cut off feed water electromagnetic valve of feed water mains and branch pipe, close the waterway completely, and cut off the occurs of the water leakage, it can also detect the specific leakage position and send the alarm information to related management person via SMS center, what’s more, on the spot the sound and light alarm will be produced.
 
 

Non-localized Leakage Detection
Non-Localized Line Leaking Collector
when the device has detected the leakage through ASC2100, it will output a relay signal through collector, it can be connected with Sitemate AE, and only takes up one switch quantity detection port.
Non-Localized Line Leaking Cable (10M)
It need to be allocated with Non-Localized Line Leaking Collector to detect whether the leaking has been happened, the cable length can be selected(no more than 30M), the price is calculated by meters.

 
 
 
7, Entrance guard system
 
The entrance guard system is consisted by door controller, entrance guard card, card reader, electronic lock, network extend device, entrance guard management software and management computer, etc. RichComm’s computer room monitor system can realize computer room in and out control, in and out information login, security guard againset theft and warn,etc. at the same time, it can provide many kinds of network functions (RS485, wireless modem, dial, TCP/IP, text message, SP).
 

Entrance Guard System
Entrance Guard Controller(one door/two door/four door WEB controller)
Entrance Guard Controller Host, provide WEB interface, so it can be visited by network,user can select according to the door quantity and the actual demands
Magnetic lock
User need to select the quantity of Magnetic lock according to the quantity of the door
Door open button
User need to select the quantity of door open button according to the quantity of the door
Card reader
Support ID card reader, user can select according to the actual demands
Fingerprint reader
Support the fingerprint authentication, the password authentication or the fingerprint + password authentication card reader,user can selected according to the actual demands
ID card
User can select according to the real situation

 
 
 
8, Video monitor system
 
RichComm’s image monitor system adapts the concept of video configuration, which can insect the image of each channel to the monitor interface random by configuration way. For large monitor system, our system can centralized manage the data and image interface of each field by electronic map way, it is very convenient. Because our system can set computer room monitor system and closed-circuit at one system, we can realize the linkage control of power environment and image, once the abnormal event occurs, computer room monitor system will pop up scene image picture, real-time video automatically, and it can also send alarm prompt and handle with the problems.
 

Video Monitor System
Infrared Hemisphere Camera
Plastic shell, with infrared cameras, 480 line, hemisphere, beautiful and simple
Infrared Hemisphere Camera(Metal shell/waterproof/explosion-proof)
Metal shell/waterproof/explosion-proof, with infrared cameras, 520 line, hemisphere, beautiful and simple
Infrared Hemisphere Network Camera
infrared hemisphere, beautiful and simple
Video Recorder(4/8/16 Circuit )
able to connect 4/8/16 circuits video, support Web interface
1TB hard disk
special used on enterprice monitor recorder

 
 
 
 
 
User Value
 
Simple installation
Standard port(RS232/RJ45),User can realize no engineering installation through simple network wiring;
Easy management
Web remote centralized management,centralized and convinience;
Simple Maintenance
Distributed and IP network architecture, users can remote configure and manage the system via
Web browser, and need not to install software, simple and convinience;
Flexible expansion:
Modular design, each monitor subsystem can work independently, they will not interfere with
each other, the upgrade and expansion are all very convinient;
Safety and reliability:
Embedded monitor host design, which can avoid the mechanical fault maximum; and it is also embedded software and hardware watchdog, can guarrantee that the system has perfect self-detective and self-recovered function, so as to guarrantee the system can run safely and reliablly;
Moderate funds investment can realize complete coverage of computer room management gradually, and enhance the productivity of the system and the input-output ratio of the users.
 
 
 
 
 
 
 
Channel Sale Value:
Expand profit model:
In many cases, the implementation of the computer room monitor project is to explore further on the basis of the original customer, therefore, the channel distributor can realize rapid business scope expansion by the least business investment, and realize the profit model expansion;
 
Improve profit ability:
The duplicability of the program reduces the construction cost; the producibility system design saves the secondary development time; at the same time of system stability improvement, our system can shorten the time of the returned money, so as to raise the business level and profitability;
 
Enhance customer loyalty:
The producibility and modular architecture system makes the study, construction and maintenance of the system easier for the channel distributor, so it is good for the comprehensive control of the project; At the same time, the implement of the new project can deepen the the depth and breadth of the cooperation with original customer, it can promote the customer loyalty while enhancing the dependence of the user.