Product function comparision
Firstly, Rack architecture computer room and UPS power environment monitoring and management products introduction.
|
Sitemate (Computer room and UPS power environment network monitoring and management products) |
|
1. 19 inches rack architecture |
|
2. Basic monitoring function |
|
UPS current, voltage, bypass and many other status network monitoring and display |
|
3. Memory function |
|
Built-in long life system clock, can realize memory function, such as |
|
1). Support task scheduler (timing self-test, open/shutdown ) |
|
2). Support history event, history data record function |
|
3). Event record, data log, SNTP, work scheduler |
|
4. Expand function |
|
Able to expand many kinds of device through RS422 port (RJ45 form), such as |
|
1). Built-in RJ45 and terminal connection port for sensor device connection(contains 4-16 circuit switch quantity,such as smoke sensor,water leak sensor,door contact …2 circuit relay output control,4-8 circuit temperature and humidity) |
|
2). Remote power control module, |
|
3). Air conditioning infrared module, |
|
4). |
|
5. Alarm function |
|
Allocated with centralized monitoring product, able to realize many kinds of alarming function, such as E-mail, Voice and broadcast, SMS alarm, voice dialing alarm, etc. |
|
6. Centralized monitoring function |
|
Allocated with centralized monitoring product, able to realize multi-brand, multi-type UPS remote centralized monitoring. |
|
MobileSite (Computer room and UPS power environment SMS monitoring and management products) |
|
Main feature and function:(Sitemate+ internal SMS alarm function) |
|
1. All the functions of Sitemate |
|
2. Built- in SMS alarming function |
|
Rackslot (Rack mountable slot, with four slots for internal monitoring cards) |
|
1. Standard rack architecture |
|
2. The device has 4 intelligent slot, can be inserted 4 SNMP or other internal monitoring cards, can realize the conversion from common internal UPS monitoring device to rack architecture, which is more suitable for modern computer room demands |
|
IP Power 2009 (Computer room and UPS network comprehensive monitoring host) |
|
1. Users only need to login one IP, and add all monitoring device to IP Power 2009, and then users can manage 5000 outlets at most at the same time. |
|
2. IP Power 2009 adopts popular 19 inches rack mountable way. |
|
3. Able to realize voice dialing alarm function. |
|
4. With the rapid development of internet, IP Power 2009 will become the best partner of intelligent UPS, and can monitor and manage UPS in no man’s condition, and send alarming information 24-hour. |
|
Netmate Lite/Netmate Lite Mini (internal or external): basic UPS network monitoring cards/ adapter |
|
1. Lowest price |
|
RichComm can provide the lowest price among the same SNMP cards |
|
2. Simple operation interface |
|
Personality simple operation interface let the customer be clear at a glance, easy control |
|
3. Flexibility |
|
Our product can be customized to the version according to the demands of the clients |
|
4. Standalone and network monitor |
|
Netmate Lite Mini can not only be used for standalone monitoring, but also can realize network monitoring, this function is convenient for the different demands of clients. |
|
5. Network centralized monitor |
|
Can realize UPS centralized monitoring and unified management of all kinds of outlets, and can also realize remote control. |
|
6. Many kinds of alarming function |
|
Allocated with centralized software can realize many kinds of alarming function, such as E-mail, Voice and broadcast, SMS alarming, voice dialing alarming, etc. |
|
Netmate II /Network II Mini (internal or external): standard UPS network monitoring cards/adapter |
|
Compared with Netmate Lite/Netmate Lite Mini, Netmate II/Netmate II Mini added the following functions: |
|
1. Memory function |
|
Built-in long life system clock, can realize memory function, such as |
|
1). Support task scheduler (timing self-test, open/shutdown ) |
|
2). Support history event, history data record function |
|
3). Event record, data log, SNTP, work scheduler |
|
2. Expand function |
|
Able to expand many kinds of device through RS422 port (RJ45 form), such as |
|
1). Temperature and humidity module, |
|
2). 4i2o signal collecting module, realize sensor connection (smoke sensor, water leak sensor, door contact, sound-light alarm), |
|
3). Remote power control module, |
|
4). Air conditioning infrared module, |
|
5). |
|
MobileMate (UPS SMS management adapter) |
|
1. Basic monitoring function |
|
UPS current, voltage, bypass and many other status network monitoring and display |
|
2. Memory function |
|
Built-in long life system clock, can realize memory function, such as |
|
1). Support task scheduler (timing self-test, open/shutdown ) |
|
2). Support history event, history data record function |
|
3). Event record, data log, SNTP, work schedular |
|
3. Expand function |
|
Able to expand many kinds of device through RS422 port (RJ45 form), such as |
|
1). Temperature and humidity module, |
|
2). 4i2o signal collecting module, realize sensor connection (smoke sensor, water leak sensor, door contact, sound-light alarm), |
|
3) remote power control module, |
|
4). Air conditioning infrared module, |
|
5). |
|
4. Alarm function |
|
Able to realize many kinds of alarming function, such as E-mail, Voice and broadcast, SMS alarm, etc. |
|
5. Centralized monitoring function |
|
Allocated with centralized monitoring product, able to realize multi-brand, multi-type UPS remote centralized monitoring. |
|
6. SMS and network two kinds of monitoring ways |
|
MobileMate can not only be used for SMS monitoring, but also can realize network monitoring, this function is convenient for the different demands of clients |
|
MobileSite (computer room power environment comprehensive SMS monitoring host) |
|
Compared with MobileMate, MobileSite adds the following function |
|
1. 19 inches rack architecture |
|
2. Built-in RJ45 and terminal connection port for sensor device connection(contains 4-16 circuit switch quantity,such as smoke sensor,water leak sensor,door contact …2 circuit relay output control,4-8 circuit temperature and humidity) |
|
Mobile SMS sending module |
|
1. Adopts high performance integration industrial GSM/GPRS module |
|
2. Support bi-frequency GSM/GPRS |
|
3. Need to allocated with SNMP monitoring card to use |
|
4. Can be used as SMS sending gateway |
|
Mobile SMS monitoring adapter |
|
1. Adopts high performance integrated industrial- class GSM/GPRS module. |
|
2. Support bi-frequency GSM/GPRS. |
|
3. Accord with ETSI GSM Phase 2+. |
|
4. Can inquiry UPS status via mobile short message; |
|
5. Compatible with multi-brand and multi-type UPS; |
|
6. Through fly letter and mobile phone,can inquiry the UPS utility, inverter, bypass, self-test running state, at the same time,it also can receive the fault alarm of the UPS anytime and anywhere. |
|
7. Realize remote centralized monitoring for multi-brand and multi-types UPS; |
|
8. Multi-user management function, can send different alarms to different mobiles (support 6 mobile phone number to the most ) |
|
9. Alarm contains equipment name, fault description, sending time. It is easy for the administrator to position the fault place accurately |
|
10. Can connect the UPS with the RS232 interface directly, it can realize the system configuration without networking, which can save the cost of paved network. |
|
11. The system equipment adapts advanced power technology, the supply-power has a wide application range, it does not only improve the equipment stability, but guarantee that the system equipment can be used in bad environment, such as substation, basement, telecommunication communication stations |